Safety Flash
Hot water fitting failure results in 3m loss of depth in diving bell
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A diving bell lost pressure during pre-dive checks following a cracked hot-water fitting. Impact from a diver’s bailout bottle was believed to have caused the failure. The team isolated the leak. The flash highlights effective drills, uncertain fitting replacement history, inspection for impact damage and recording critical components in planned maintenance systems.