Safety Flash

Failure of high pressure fitting

IMCAInternational Marine Contractors AssociationIMCA SF 12/05

Failure of high pressure fitting

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A half-inch high-pressure fitting failed at 200 bar during reclaimed diving-gas cleaning aboard a dive vessel. Gas escaped and the whip check failed, without injury. The flash discusses likely thread wear, uncertain whip-check positioning and rating, revised connector inspection and testing, and proposed five-year replacement of fittings subject to wear.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/05
Date
30 December 2005
Topic
Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Hose
Control
Energy and Process Isolation, Positive Retention and Reliable Securing, Preventive Maintenance
Sector
Marine Industry
Setting
Vessel