Safety Alert

Safety Alert 374 - Air Compressor Flaws Lead to Engine Fire

BSEEBureau of Safety and Environmental EnforcementBSEE Safety Alert 374

Safety Alert 374 - Air Compressor Flaws Lead to Engine Fire

Read at BSEEOpens the publisher’s page on bsee.gov

Summary

An air-compressor fire on a Gulf of Mexico production platform followed regulator diaphragm rupture and hydraulic fluid release through PSV outlets. Fluid ignited on the hot exhaust manifold after shutdown. The alert recommends considering condition checks, additional pressure shutdown protection, controlled discharge arrangements and periodic diaphragm inspections.

Topics

About This Record
Publisher
Bureau of Safety and Environmental Enforcement
Type
Safety Alert
Reference
BSEE Safety Alert 374
Date
11 December 2019
Topic
Fire, Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Rotating Machinery, Valve
Control
Job Safety Analysis, Pre-Use Checks, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-safety-alert-374 · added 2 September 2026