A well-choke cap failure on a production platform released natural gas that ignited, burning one person. Investigation found worn and eroded acme threads, with similar deterioration on other chokes. Emergency shutdown limited the fire. The operator planned regular thread cleaning, inspection, gauging, replacement where necessary and protective lubrication.