Summary

A saturation diving incident involved air supplied instead of oxygen after ordering errors and incomplete delivery, connection and gas-analysis checks. Automatic metabolic make-up introduced the incorrect gas into the chamber; no ill effects were found. Actions addressed procedural compliance, authorised delivery verification and portable analyser use before connection.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 06/12
Date
25 June 2012
Topic
Human Factors
Activity
Saturation Diving
Equipment
Gas Cylinder, Gas Detector
Control
Competence and Training, Operating and Work Procedures, Pre-Use Checks