Safety Flash

Lead-acid battery explosion

IMCAInternational Marine Contractors AssociationIMCA SF 06/21

Lead-acid battery explosion

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A generator starting incident destroyed the top of a lead-acid battery case. The flash identifies a hot negative-terminal connection that would have ignited any excess hydrogen accumulated in the battery box. Actions include checking connections, following installation instructions and considering batteries that do not release hydrogen during charging.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 06/21
Date
23 February 2021
Topic
Electrical Safety, Explosion, Hydrogen Safety
Activity
Inspection and Maintenance
Control
Operating and Work Procedures
Link
Checked , working
Record
imca-sf-06-21-lead-acid-battery-explosion · added 1 September 2026

Report a problem with this record