Safety Flash

Two battery issues – Step Change

IMCAInternational Marine Contractors AssociationIMCA SF 12/19

Two battery issues – Step Change

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Two battery incidents illustrate different hazards: a lifeboat lead-acid starter battery exploded after repeated overcharging, while a lithium-ion battery caught fire following water exposure and short-circuiting of inspection equipment. Lessons address equipment suitability, clear charging instructions, workforce competence, protection against water ingress and care when drying equipment.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/19
Date
28 May 2019
Topic
Electrical Safety, Explosion, Fire, Hydrogen Safety
Activity
Inspection and Maintenance
Equipment
Lifeboat
Control
Competence and Training, Operating and Work Procedures
Link
Checked , working
Record
imca-sf-12-19-two-battery-issues-step-change · added 1 September 2026