Summary
This safety flash describes a lifeboat recovery incident during routine planned maintenance. After personnel re-boarded the vessel, a noise prompted an immediate stop with the boat approximately one metre above deck. Inspection found a disintegrated davit sheave perimeter, which had allowed the falls wire to leave the sheave and become trapped.
Classifications: Mechanical failure; equipment failure.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Lifting operations; load lifting; hoisting.
Classifications: Lifeboat; survival craft.
Classifications: Wire rope; steel wire rope.
Classifications: Vessel; aboard ship; onboard vessel.
Summary
A lifeboat davit sheave disintegrated during recovery, causing the falls wire to leave the sheave and become trapped.