Safety Flash

Near-miss: Bell umbilical damage incident

IMCAInternational Marine Contractors AssociationIMCA SF 08/12

Near-miss: Bell umbilical damage incident

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During diving bell recovery, insufficient umbilical tension allowed trapping between the cursor and bell, damaging the sheath and causing a small gas leak. Divers remained unharmed. The flash examines supervisor distraction and a visual-only differential alarm, recording umbilical re-termination, installation of an audible alarm and revised recovery risk assessments.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/12
Date
24 July 2012
Topic
Crushing and Pinch Points, Human Factors
Activity
Diving Operations
Equipment
Diver Umbilical, Diving Bell, Operator Displays and Control Interfaces
Control
Alarm Management, Risk Assessment, Stop-Work Authority
Setting
Vessel
Link
Checked , working
Record
imca-sf-08-12-near-miss-bell-umbilical-damage-incident · added 1 September 2026