Safety Flash

ROV main lift umbilical failure

IMCAInternational Marine Contractors AssociationIMCA SF 08/15

ROV main lift umbilical failure

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An ROV lift umbilical parted during recovery, dropping the vehicle to the seabed in 1360 m water depth. Recovery found no damage or injuries. Investigation identified hidden internal damage linked to inadequate lubricant penetration despite certification and scheduled maintenance. The flash recommends strand inspections and improved destructive-test reporting.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/15
Date
5 June 2015
Topic
Corrosion, Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations, ROV Operations
Equipment
Remotely Operated Vehicle, Wire Rope
Control
Preventive Maintenance
Sector
Marine Industry
Setting
Subsea, Vessel
Link
Checked , working
Record
imca-sf-08-15-rov-main-lift-umbilical-failure · added 1 September 2026

Report a problem with this record