Safety Flash

Failure of lifting equipment: Dropped ROV

IMCAInternational Marine Contractors AssociationIMCA SF 09/13

Failure of lifting equipment: Dropped ROV

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An offshore lifting incident involved a fibre sling failing and an ROV/TMS assembly dropping from 30 cm onto a vessel’s deck, damaging the ROV without injuries. Findings included unsuitable rigging, an unprotected sharp edge, absent supervision and no lift plan. Preventative actions address planning, supervision, certified equipment and sling protection.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 09/13
Date
18 June 2013
Topic
Dropped Objects, Mechanical Failure
Activity
Lifting Operations, Rigging
Equipment
Lifting Accessories
Control
Control of Work, Lifting Plan, Operational Supervision
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-09-13-failure-of-lifting-equipment-dropped-rov · added 1 September 2026