Safety Flash

Uncontrolled movement of A-frame

IMCAInternational Marine Contractors AssociationIMCA SF 10/09

Uncontrolled movement of A-frame

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An A-frame moved unexpectedly during umbilical re-attachment, lifting the tether management system approximately one metre off the deck while a technician was on top. No injuries or equipment damage occurred. Investigation identified a failed proportional valve driver. Subsequent changes addressed hydraulic isolation, work procedures, risk assessments and control-system protection.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 10/09
Date
10 July 2009
Topic
Line of Fire, Mechanical Failure
Activity
Inspection and Maintenance, Working at Height
Equipment
Valve, Winch
Control
Energy and Process Isolation, Operating and Work Procedures, Risk Assessment