Investigation Report

Gas-Lift Tubing Rupture Injured Technicians During Casing-Valve Maintenance

BSEEBureau of Safety and Environmental Enforcement

03-12-2023 1630 G02213 MP 311 Injury Requiring Evacuation - LTA (>3 days), Other - Pressure Release

Read at BSEEOpens the document on bsee.gov

Summary

Investigates injuries to two technicians during casing-valve maintenance on Main Pass 311 B. Unexpected casing pressure ruptured gas-lift tubing, knocking both workers down. Findings address misleading SCADA readings, unmonitored casing pressure, omitted diagnostics and pre-job checks, and discrepancies between installed equipment and approved drawings. Subsequent changes introduced direct pressure readings.

Topics

About This Record
Original title
03-12-2023 1630 G02213 MP 311 Injury Requiring Evacuation - LTA (>3 days), Other - Pressure Release
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Falls from Height, Line of Fire, Mechanical Failure, Pressure Systems, Well Integrity
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines, Valve
Control
Evacuation, Escape and Rescue, Energy and Process Isolation, Risk Assessment, Safety Communication
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-4906351a66 · added 2 October 2026