Safety Flash

Oxygen regulator explodes causing injury

IMCAInternational Marine Contractors AssociationIMCA SF 10/11

Oxygen regulator explodes causing injury

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An oxygen regulator exploded during a diving-gas quad changeover aboard a vessel, burning a gasman’s hand. The flash discusses possible valve contamination, unsuitable protective equipment and difficulty isolating oxygen after opening all cylinders. Actions include cleanliness checks, risk assessment and a revised connection sequence with slow pressure equalisation.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 10/11
Date
16 September 2011
Topic
Explosion, Hand and Finger Injuries, Pressure Systems
Activity
Diving Operations
Equipment
Gas Cylinder, Personal Protective Equipment, Valve
Control
Energy and Process Isolation, Operating and Work Procedures, Pre-Use Checks, Risk Assessment
Setting
Vessel
Link
Checked , working
Record
imca-sf-10-11-oxygen-regulator-explodes-causing-injury · added 1 September 2026