Safety Flash
Near-miss: Collapse of ROV launch and recovery system (LARS)
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An ROV launch and recovery A-frame collapsed during demobilisation after securing bolts were removed from both supporting hydraulic rams and their feet struck with a sledge hammer. Two supervisors escaped injury. The flash highlights ignored procedures, inadequate work control and competence, and a missed opportunity to stop unsafe work.