Safety Flash

LTI as a result of a load dropped from lifting magnet

IMCAInternational Marine Contractors AssociationIMCA SF 11/17

LTI as a result of a load dropped from lifting magnet

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A permanent lifting magnet dropped a polished metal load onto a worker’s hand, causing a lost-time injury. Thicker protective foil reduced magnetic holding capacity, leaving no safety margin. The flash examines air-gap sensitivity, inadequate work instructions and technical understanding, and the need to share equipment limitations and undocumented practices.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 11/17
Date
22 May 2017
Topic
Dropped Objects, Hand and Finger Injuries, Line of Fire
Activity
Lifting Operations
Equipment
Magnetic Lifter
Control
Competence and Training, Job Safety Analysis, Operating and Work Procedures, Safety Communication