Safety Flash
LTI as a result of a load dropped from lifting magnet
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A permanent lifting magnet dropped a polished metal load onto a worker’s hand, causing a lost-time injury. Thicker protective foil reduced magnetic holding capacity, leaving no safety margin. The flash examines air-gap sensitivity, inadequate work instructions and technical understanding, and the need to share equipment limitations and undocumented practices.