Summary
Crosby’s inspection notice concerns hoist rings with missing retaining pins, allowing hinge pins to escape while unloaded. It describes outward prying or pulling and twisting checks on both hinge pins, acceptable movement, inspection marking, and removal from service for rings with inadequately secured pins.
Classifications: Mechanical failure; equipment failure.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Lifting accessories; lifting gear; rigging gear.
Classifications: Functional testing; function test.
Classifications: Positive retention and reliable securing.
Summary
The Crosby Group has asked IMCA to circulate the following information as part of a Safety Flash
IMCA SF 11/23. Themes: crane and rigging, inspection and maintenance.