Safety Flash

Near miss: Steam and water released from filter

IMCAInternational Marine Contractors AssociationIMCA SF 11/23

Near miss: Steam and water released from filter

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A mechanic cleaning boiler circulation pump strainers encountered an unexpected steam and water release. The isolation valve had not fully closed; a supervisor subsequently closed it further. Revised procedures specified opening the filter bypass before inlet and outlet isolation, followed by upstream and downstream draining and purging to ensure zero energy.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 11/23
Date
3 May 2023
Topic
Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Valve
Control
Energy and Process Isolation, Operating and Work Procedures
Link
Checked , working
Record
imca-sf-11-23-near-miss-steam-and-water-released-from-filter · added 1 September 2026