Safety Flash

Failure of cable socks (Chinese fingers) on subsea rigging

IMCAInternational Marine Contractors AssociationIMCA SF 12/01

Failure of cable socks (Chinese fingers) on subsea rigging

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Cable socks supporting a subsea dewatering hose slipped along a winch wire, overloading and breaking socks above. Investigation identified unsuitable grip, swell-related loading, an unrepresentative deck test and inadequate assessment of a later rigging change. Replacement rigging using support-wire clamps enabled successful completion of dewatering.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 12/01
Date
2 October 2001
Topic
Mechanical Failure, Risk Management
Activity
Rigging
Equipment
Hose, Lifting Accessories, Wire Rope
Control
Functional Testing, Management of Change, Risk Assessment
Setting
Subsea, Vessel
Link
Checked , working
Record
imca-sf-12-01-failure-of-cable-socks-chinese-fingers-on-subsea-rigging · added 1 September 2026