Safety Flash

Use of pre-mixed nitrox gases

IMCAInternational Marine Contractors AssociationIMCA SF 13/09

Use of pre-mixed nitrox gases

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diving near miss involved third-party premixed nitrox with incorrect oxygen content. Monitoring detected 32% against an expected 36%, prompting suspension; subsequent testing found approximately 15% in some cylinders. Lessons emphasise supplier quality assurance, analysis before first use, in-line analysers and attention to individual bottles within racks.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 13/09
Date
7 September 2009
Topic
Oxygen Deficiency
Activity
Diving Operations
Equipment
Gas Cylinder, Gas Detector
Control
Contractor Management, Pre-Use Checks
Link
Checked , working
Record
imca-sf-13-09-use-of-pre-mixed-nitrox-gases · added 1 September 2026