Safety Flash

High potential near-miss: Poor O₂ content in supplied air – diver temporarily lost consciousness

IMCAInternational Marine Contractors AssociationIMCA SF 01/16

High potential near-miss: Poor O₂ content in supplied air – diver temporarily lost consciousness

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diver briefly lost consciousness on a diving support vessel after switching to a breathing-air quad containing around 3% oxygen. Tenders removed his helmet and he recovered. The flash examines supplied-gas quality assurance, an oxygen analyser that failed to alarm, and proposed pre-dive checklist changes to clear residual gas before introducing a new supply.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/16
Date
7 January 2016
Topic
Oxygen Deficiency
Activity
Diving Operations
Equipment
Breathing Apparatus, Gas Cylinder, Gas Detector
Control
Emergency Response, Atmospheric Gas Testing, Operating and Work Procedures, Pre-Use Checks
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-01-16-high-potential-near-miss-poor-o2-content-in-supplied-air-diver-temporarily-lost · added 1 September 2026

Report a problem with this record