Summary
A diver sustained a thumb and index-finger crush injury while positioning a round sling at a subsea hang-off point. The investigation identified restricted space, repeated unhooking under wave surge and difficult splash-zone conditions. The flash describes emergency recovery and evacuation, sling banding, planned tail-rope use and communication of changed procedures.