Safety Flash
LTI: Finger injury during emergency recovery of ROV
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
During emergency ROV recovery using an FRC and crane, a worker’s left ring finger was pinched while releasing a hook secured to the crane wire, causing amputation to approximately the nail bed. The flash identifies an unplanned, unassessed release step and records revised procedures, risk assessment and regular recovery training.