Safety Flash

Bell re-claim failure resulting in minor injury

IMCAInternational Marine Contractors AssociationIMCA SF 13/14

Bell re-claim failure resulting in minor injury

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A saturation-diving incident at 110 msw injured a bellman when a reclaim-line water trap ruptured. An inverted check valve allowed retained exhaust gas to pressurise the trap following a compressor solenoid failure. The flash examines refurbishment errors, filter-change maintenance and inspections that missed the incorrectly fitted component.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 13/14
Date
17 July 2014
Topic
Line of Fire, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance, Saturation Diving
Equipment
Diving Bell, Valve
Control
Independent Audit and Verification, Preventive Maintenance
Setting
Subsea
Link
Checked , working
Record
imca-sf-13-14-bell-re-claim-failure-resulting-in-minor-injury · added 1 September 2026