Safety Flash

Main ROV lift umbilical parted

IMCAInternational Marine Contractors AssociationIMCA SF 13/14

Main ROV lift umbilical parted

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An ROV recovery incident involved a parted lift umbilical, with the vehicle and tether management system falling to the seabed and later being recovered. Investigation identified unrestricted winch pull with a short, thin umbilical and malfunctioning latches. Corrective actions addressed latch indications and procedures limiting pull below umbilical breaking strain.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 13/14
Date
17 July 2014
Topic
Dropped Objects, Mechanical Failure
Activity
Lifting Operations, ROV Operations
Equipment
Remotely Operated Vehicle, Winch
Control
Operating and Work Procedures
Sector
Marine Industry
Setting
Subsea
Link
Checked , working
Record
imca-sf-13-14-main-rov-lift-umbilical-parted · added 1 September 2026