Safety Flash

Main ROV lift wire umbilical and bullet parted

IMCAInternational Marine Contractors AssociationIMCA SF 27/19

Main ROV lift wire umbilical and bullet parted

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An inspection-class ROV and its tether management system fell to the seabed during recovery after the main lift connection parted. The flash examines a recently re-terminated, load-tested bullet connection, failed potting compound and high ambient temperatures, and records procedural changes addressing temperature limits, compound quantities and storage details.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 27/19
Date
22 November 2019
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations, ROV Operations
Equipment
Remotely Operated Vehicle, Wire Rope
Control
Competence and Training, Functional Testing, Operating and Work Procedures
Sector
Marine Industry
Setting
Subsea, Vessel
Link
Checked , working
Record
imca-sf-27-19-main-rov-lift-wire-umbilical-and-bullet-parted · added 1 September 2026