Safety Flash

Don’t put your finger in the wrong place: Failure to isolate equipment causes serious finger injury

IMCAInternational Marine Contractors AssociationIMCA SF 13/19

Don’t put your finger in the wrong place: Failure to isolate equipment causes serious finger injury

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An ROV manipulator repair resulted in the loss of approximately 1 cm of a worker’s left index finger while checking clevis and hydraulic shaft alignment. The flash identifies live hydraulics, unconsulted manuals and inadequate task risk assessment, and recommends hydraulic isolation, lockout/tagout and adherence to technical instructions.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 13/19
Date
4 June 2019
Topic
Crushing and Pinch Points, Hand and Finger Injuries
Activity
Inspection and Maintenance
Equipment
Remotely Operated Vehicle
Control
Energy and Process Isolation, Lockout and Tagout, Operating and Work Procedures, Risk Assessment