Safety Flash

Near miss: High voltage arc inside tether termination manifold

IMCAInternational Marine Contractors AssociationIMCA SF 13/25

Near miss: High voltage arc inside tether termination manifold

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A dislodged HPU conductor caused arcing inside an ROV tether termination manifold. Subsequent checks identified reduced insulation resistance and gas, whose origin was unconfirmed without testing. The flash examines unapproved termination lugs and records re-termination, system testing and recommendations to assess crimping tools and review procedures and gas-venting precautions.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 13/25
Date
31 July 2025
Topic
Arc Flash, Electrical Safety
Activity
Electrical Work, Inspection and Maintenance, ROV Operations
Equipment
Hand Tools, Remotely Operated Vehicle
Control
Functional Testing, Energy and Process Isolation, Operating and Work Procedures
Link
Checked , working
Record
imca-sf-13-25-near-miss-high-voltage-arc-inside-tether-termination-manifold · added 1 September 2026