Safety Flash

Failure of gas supply to diving bell

IMCAInternational Marine Contractors AssociationIMCA SF 14/09

Failure of gas supply to diving bell

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Checks at a storage depth of 102 metres revealed insufficient breathing-gas flow in both diving bells of a new system. Workshop testing reproduced the problem, and higher-performance regulators restored adequate flow. The flash recommends full functional testing at maximum working depths following significant changes, rather than relying on purging.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 14/09
Date
2 October 2009
Topic
Pressure Systems
Activity
Diving Operations
Equipment
Breathing Apparatus, Diving Bell
Control
Functional Testing, Management of Change
Setting
Subsea
Link
Checked , working
Record
imca-sf-14-09-failure-of-gas-supply-to-diving-bell · added 1 September 2026