Safety Flash

Diver experienced an air flow restriction

IMCAInternational Marine Contractors AssociationIMCA SF 10/22

Diver experienced an air flow restriction

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A surface-supplied diver experienced restricted air flow at 23msw and the dive was aborted without injury. Investigation identified a needle valve that failed to open properly, with possible overtightening linked to premature equipment fatigue. Actions included valve replacement, revised pre-dive checks and operating procedures, and a team emergency debrief.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 10/22
Date
21 April 2022
Topic
Mechanical Failure, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Breathing Apparatus, Diver Umbilical, Valve
Control
Emergency Response, Operating and Work Procedures, Pre-Use Checks, Preventive Maintenance
Sector
Marine Industry
Setting
Subsea
Link
Checked , working
Record
imca-sf-10-22-diver-experienced-an-air-flow-restriction · added 1 September 2026