Safety Flash

Failure of first stage regulator low pressure (LP) blanking cap

IMCAInternational Marine Contractors AssociationIMCA SF 30/21

Failure of first stage regulator low pressure (LP) blanking cap

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A diver’s bailout regulator leaked after a low-pressure port blanking cap failed. The dive ended and both divers were recovered safely. The flash records replacement of caps and O-rings, specified torque checks in work orders, and assessment of regulators used for more than ten years for possible replacement.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 30/21
Date
8 November 2021
Topic
Mechanical Failure, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Breathing Apparatus
Control
Operating and Work Procedures, Preventive Maintenance
Link
Checked , working
Record
imca-sf-30-21-failure-of-first-stage-regulator-low-pressure-lp-blanking-cap · added 1 September 2026