Safety Flash

Damaged high pressure content gauge hoses on bail-outs

IMCAInternational Marine Contractors AssociationIMCA SF 08/19

Damaged high pressure content gauge hoses on bail-outs

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Two diving incidents within 24 hours involved depleted bail-out bottles and leaking high-pressure content gauge hoses. Examination identified cuts and bending-related damage near ferrule connectors despite bend restrictors and regular checks. The flash compares hose constructions and notes that annual replacement of one type may be required, depending on usage.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 08/19
Date
25 April 2019
Topic
Mechanical Failure, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Breathing Apparatus, Hose
Control
Pre-Use Checks, Preventive Maintenance
Link
Checked , working
Record
imca-sf-08-19-damaged-high-pressure-content-gauge-hoses-on-bail-outs · added 1 September 2026