Safety Flash

Bail-out whip failures

IMCAInternational Marine Contractors AssociationIMCA SF 01/10

Bail-out whip failures

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

Reports failures of diver bail-out high-pressure contents whips near swage fittings. The member had not established the exact cause, while manufacturer investigations identified bending or crimping damage. Describes batch quarantine, planned alternative-design replacement and interim measures covering hose inspection, bend restriction and avoidance of loads on whips and fittings.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 01/10
Date
9 February 2010
Topic
Mechanical Failure, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Hose
Control
Pre-Use Checks
Link
Checked , working
Record
imca-sf-01-10-bail-out-whip-failures · added 1 September 2026