Safety Flash

Grit hose parting: Near-miss incident

IMCAInternational Marine Contractors AssociationIMCA SF 13/01

Grit hose parting: Near-miss incident

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A grit hose separated from its deck coupling during a diver’s grit-blasting operation, without injury or damage. The flash records immediate compressor shutdown and an onboard safety meeting, then specifies pre-use hose and clamp checks, rope restraints, coupling insurance wire and continuous compressor and blast-pot attendance.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 13/01
Date
1 November 2001
Topic
Line of Fire, Mechanical Failure, Pressure Systems
Activity
Diving Operations, Inspection and Maintenance
Equipment
Hose
Control
Operational Supervision, Positive Retention and Reliable Securing, Pre-Use Checks, Safety Communication
Setting
Vessel
Link
Checked , working
Record
imca-sf-13-01-grit-hose-parting-near-miss-incident · added 1 September 2026

Report a problem with this record