Safety Flash

Sudden disconnection of pressurised hose

IMCAInternational Marine Contractors AssociationIMCA SF 24/24

Sudden disconnection of pressurised hose

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During vessel maintenance, a hose disconnected while residual water was pumped from a cofferdam at approximately 5.9–6 bar. Nobody was struck or injured. The flash identifies absent whip arrestors, missed pre-use checks and an apparently worn coupling, and recommends secondary securing, coupling inspection and sufficient onboard spares.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 24/24
Date
17 December 2024
Topic
Line of Fire, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Hose
Control
Positive Retention and Reliable Securing, Pre-Use Checks, Risk Assessment
Sector
Marine Industry
Setting
Vessel