Summary
During vessel maintenance, a hose disconnected while residual water was pumped from a cofferdam at approximately 5.9–6 bar. Nobody was struck or injured. The flash identifies absent whip arrestors, missed pre-use checks and an apparently worn coupling, and recommends secondary securing, coupling inspection and sufficient onboard spares.
Classifications: Line of fire; struck-by hazards.
Classifications: Mechanical failure; equipment failure.
Classifications: Pressure systems; stored pressure; pressurised systems; pressurized systems.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Hose; flexible hose.
Classifications: Positive retention and reliable securing.
Classifications: Pre-use checks; pre-use inspection.
Classifications: Risk assessment; hazard assessment.
Classifications: Marine industry; shipping industry; maritime sector.
Classifications: Vessel; aboard ship; onboard vessel.
Summary
A contractor was performing maintenance on the bulk cargo methanol system on deck of a vessel.