Safety Flash

Fuel spray fire

IMCAInternational Marine Contractors AssociationIMCA SF 15/18

Fuel spray fire

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A vessel’s cracked fuel-system isolating valve released approximately 1 m³ of fuel. Engine vibration and assembly weight caused the failure following a pipework alteration. The flash describes replacement with a stainless-steel fitting, installation of a spray deflector and lessons on assessing short- and long-term consequences through management of change.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 15/18
Date
20 July 2018
Topic
Hydrocarbon Release, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines, Valve
Control
Ignition Source Control, Management of Change
Sector
Marine Industry
Setting
Vessel
Link
Checked , working