Summary
An ROV manipulator fuse bolt ejected its head during pre-dive testing, narrowly missing a technician without injury. Investigation linked the failure to damage sustained during heavy work on the previous dive. The flash recommends manual jaw operation before energising hydraulics, directing arms away from people and assets, and controlling access during deck checks.
Classifications: Line of fire; struck-by hazards.
Classifications: Mechanical failure; equipment failure.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: ROV operations; remotely operated vehicle operations.
Classifications: Remotely operated vehicle; ROV; underwater robot.
Classifications: Exclusion zones; red zones; restricted access zones.
Classifications: Functional testing; function test.
Classifications: Operating and work procedures.
Classifications: Pre-use checks; pre-use inspection.
Summary
A Member has reported an incident in which a crew member was narrowly missed by the head of a fuse bolt which had been shot out of a remotely operated vehicle (ROV) manipulator arm at high speed.