Safety Flash

MSF: Engine damage after routine maintenance

IMCAInternational Marine Contractors AssociationIMCA SF 16/21

MSF: Engine damage after routine maintenance

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

An offshore platform supply vessel stopped an engine following a high-temperature alarm. Inspection found valve-gear damage, 86 running hours after valve adjustments. Evidence indicated a loose adjusting-screw locking nut, most likely insufficiently tightened during reassembly. Lessons emphasise manufacturer requirements, careful reassembly checks and torque-wrench verification.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 16/21
Date
9 June 2021
Topic
Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Hand Tools, Rotating Machinery
Control
Operating and Work Procedures
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-16-21-msf-engine-damage-after-routine-maintenance · added 1 September 2026