Safety Flash

LTI – Struck when anchor wire end pulled free of drum clamps

IMCAInternational Marine Contractors AssociationIMCA SF 16/22

LTI – Struck when anchor wire end pulled free of drum clamps

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crew member suffered skull fractures when an anchor wire whipped over a winch drum during wire replacement. Vessel movement tensioned the wire connected to a shoreside spooler; stoppers failed and loosened clamps released the end. The flash examines inadequate risk assessment, stopper arrangements and missing safety chains, stressing better planning.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 16/22
Date
4 July 2022
Topic
Line of Fire, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Winch, Wire Rope
Control
Exclusion Zones, Positive Retention and Reliable Securing, Risk Assessment, Safety Communication
Sector
Marine Industry
Setting
Port and Quayside, Vessel
Link
Checked , working
Record
imca-sf-16-22-lti-struck-when-anchor-wire-end-pulled-free-of-drum-clamps · added 1 September 2026