During vessel transit, rolling pressed a crew member against a flexible Perspex guard, activating emergency shutdown buttons and cutting power to both fuel pumps. Main engines were unavailable for 35 minutes. The flash discusses protective-cover suitability, two-action activation and accessible control placement, with temporary guard strengthening pending permanent replacement.