Safety Flash

High potential near-miss: Incompatible pillar valve assembly

IMCAInternational Marine Contractors AssociationIMCA SF 18/13

High potential near-miss: Incompatible pillar valve assembly

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash describes a pillar-valve failure while charging a diver’s twin bailout set. The investigation identified mixed imperial and metric cylinders, absent management of change and forced valve insertion without investigating resistance. Corrective actions included metric-only components, thread measurement, parts marking and training in management of change.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 18/13
Date
20 December 2013
Topic
Mechanical Failure, Pressure Systems
Activity
Diving Operations
Equipment
Breathing Apparatus, Gas Cylinder, Valve
Control
Competence and Training, Management of Change
Link
Checked , working
Record
imca-sf-18-13-high-potential-near-miss-incompatible-pillar-valve-assembly · added 1 September 2026