Safety Flash

USCG: Unexpected Dangers: Lifeboat Remote Control Wires

IMCAInternational Marine Contractors AssociationIMCA SF 18/22

USCG: Unexpected Dangers: Lifeboat Remote Control Wires

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash describes two lifeboat launching failures involving remote control wires: wire parting associated with poor spooling, followed by unexpected payout after replacement. The second event caused erratic lowering and a list exceeding 90 degrees. It highlights visual inspection, shackle condition and company requirements for test lowering without crew.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 18/22
Date
22 July 2022
Topic
Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Lifeboat, Winch
Control
Functional Testing, Operating and Work Procedures, Pre-Use Checks
Sector
Marine Industry
Setting
Vessel
Link
Checked , working
Record
imca-sf-18-22-uscg-unexpected-dangers-lifeboat-remote-control-wires · added 1 September 2026