Safety Flash

USCG: Hidden corrosion on deck fittings can cause dangerous failures

IMCAInternational Marine Contractors AssociationIMCA SF 25/22

USCG: Hidden corrosion on deck fittings can cause dangerous failures

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

This flash describes corroded D-ring securing straps failing during hatch-cover positioning aboard a vessel, with sling snap-back causing a severe head injury. It highlights missing testing and replacement records, concealed corrosion and ageing fittings. USCG recommendations address high-risk lifting-point identification, inspection, possible gauging or testing, safe lifting limits and scheduled maintenance.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 25/22
Date
10 November 2022
Topic
Corrosion, Line of Fire, Structural and Asset Integrity
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Lifting Accessories
Control
Non-Destructive Testing, Preventive Maintenance
Sector
Marine Industry