Safety Flash

Near miss: Dropped object during lifeboat testing

IMCAInternational Marine Contractors AssociationIMCA SF 25/23

Near miss: Dropped object during lifeboat testing

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

During lifeboat launch testing, a 7 kg turnbuckle and shackle fell 23 m onto the boat near a worker, who was unharmed. The closed turnbuckle concealed inadequate thread engagement. Actions included fleet inspections, replacement with inspectable open turnbuckles and revised pre-launch DROPS inspection procedures.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 25/23
Date
30 October 2023
Topic
Dropped Objects, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Lifeboat, Lifting Accessories
Control
Operating and Work Procedures, Pre-Use Checks
Sector
Marine Industry