Safety Flash

Failure of personal isolation procedures: Crane became damaged when it was used inappropriately

IMCAInternational Marine Contractors AssociationIMCA SF 29/23

Failure of personal isolation procedures: Crane became damaged when it was used inappropriately

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A crane aboard a vessel in dry dock was damaged when crew attempted to operate it during hydraulic repairs. Personal isolation had been used across several days by multiple people and removed for testing. The flash highlights inadequate risk assessment, the missing permit to work and restrictions on personal isolation.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 29/23
Date
18 December 2023
Topic
Human Factors, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Crane
Control
Energy and Process Isolation, Operating and Work Procedures, Permit to Work, Risk Assessment
Sector
Marine Industry
Setting
Vessel