Safety Flash

Line of fire near miss during lifting operations

IMCAInternational Marine Contractors AssociationIMCA SF 29/23

Line of fire near miss during lifting operations

Read at IMCAOpens the publisher’s page on imca-int.com

Summary

A banksman narrowly avoided a structure being landed on a vessel’s back deck; an adjacent container was damaged. Inadequately spaced bumper bars allowed load rotation and were wrongly relied upon for personnel protection. The flash discusses exclusion zones, unassessed changes and differences between planned and actual work.

Topics

About This Record
Publisher
International Marine Contractors Association
Type
Safety Flash
Reference
IMCA SF 29/23
Date
18 December 2023
Topic
Human Factors, Line of Fire
Activity
Lifting Operations
Control
Exclusion Zones, Management of Change