Safety Flash
Air cylinders – Differences in working pressure and valve types
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
Incorrect SCBA cylinders were supplied, with different capacities and working pressures from those ordered. Compatible filling connections could allow reduced air capacity, while valve-head types were also incorrectly specified. The flash identifies supplier assumptions, purchasing checks and incomplete specifications, and calls for better communication between requesters, purchasing staff and vendors.