Investigation Report
Fire in the engine room on the suction dredger Arco Avon with loss of 1 life
Read at MAIBOpens the publisher’s page on gov.uk
Summary
Investigation of a fatal engine-room fire aboard Arco Avon during an attempted fuel-pipe repair. It identifies portable angle-grinder sparks as the probable ignition source and examines pipe fretting, hot-work controls, lone working, protective clothing, CO2 system operation and medical response. Recommendations address maintenance inspections and safety-management implementation.