Investigation Report

Electrical Fire in Dynamic Positioning Controls Disabled Thrusters

BSEEBureau of Safety and Environmental Enforcement

09-30-2009 10:55 G20082 GC/640 Fire - Incident > $25K - Required Muster

Read at BSEEOpens the document on bsee.gov

Summary

An investigation documents an electrical fire in the Discoverer Clear Leader’s dynamic positioning controls. Cooling-system cracks allowed water into electrical cabinets, disabling six thrusters and causing the rig to drift 15½ ft off location. Personnel mustered, power and position were restored, and control logic was subsequently modified to respond better to power demands.

Topics

About This Record
Original title
09-30-2009 10:55 G20082 GC/640 Fire - Incident > $25K - Required Muster
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Electrical Safety, Fire, Loss of Station Keeping
Activity
Drilling, Dynamic Positioning
Equipment
Switchgear
Control
Emergency Response, Energy and Process Isolation
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-0495f4451b · added 2 October 2026