Investigation Report

Generator Diesel-Engine Fire During Completion Operations

BSEEBureau of Safety and Environmental Enforcement

03-03-2022 03:15 G12136 EW 873 Fire, Incident >$25K: Generator, Required Muster

Read at BSEEOpens the document on bsee.gov

Summary

Investigates a generator diesel-engine fire during completion operations at Ewing Banks Platform A. A failed piston rod breached the engine housing, spraying hot oil onto stored air filters. Crew extinguished the fire and mustered without reported injuries. Follow-up actions prohibited flammable storage in engine rooms and planned a maintenance review.

Topics

About This Record
Original title
03-03-2022 03:15 G12136 EW 873 Fire, Incident >$25K: Generator, Required Muster
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Mechanical Failure
Equipment
Rotating Machinery
Control
Emergency Response, Fire Protection, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-076fe9111e · added 2 October 2026

Report a problem with this record